AC Invoices
Effect: loss of efficiency, heat is transferred back into house, high energy bills, loss of cooling capacity, eventual motor failure, excessive wear and tear on compressor and parts. 100% failure rate.
Solution: Chemically clean condenser - this will help allow heat transfer, increase efficiency, prolong the life of unit, increase cooling capacity, reduce energy bills, help prevent failure. Purchase service contract!!!!
Effect: Motor becomes noisy, loss of efficiency, heat is transferred back into house, high energy bills, loss of cooling capacity, eventual motor failure, excessive wear and tear on compressor and parts. 100% failure rate.
Solution: Replace motor and clean condenser. While the motor could still be, running and may last a while longer before failure. It will probably fail on a holiday or a weekend when it cost more to fix it.
Cost will vary depending on the motor size and HP.
Effect: Loss of refrigerant, loss of efficiency, high energy bills, loss of cooling capacity, unit could freeze up, constantly having to put refrigerant in unit. Could be very costly!
Solution: Replace schrader valve, this will stop the leak. Some schrader valves cannot be replaced, therefore sealing the cap with a good lock cap with rubber o ring will seal the leak. Replace service valve.
Solution: Replace schrader valve caps, this will stop the leak. Make sure the cap is a good lock cap or one with rubber o ring that will seal the leak. Most techs have additional caps in their tool box.Â
Replacing the caps or adding caps when missing is essential
Solution: Replace service valve , this will stop the leak. Make sure the service valve is soldered back in using dry nitrogen and some sort of cooling agent, thermos trap, cool burst or wet rag. To prevent overheating.
Replacing the valve, may require recovering refrigerant.
Effect: A system running low on refrigerant will cause low capacity, freezing up, high energy bills, excessive wear and tear on compressor.
Solution: Replace drier, pull a vacuum charge the system. If an R-22 system consider replacement.
Effect: possibly an eventual leak.
Solution: Replace drier / (sand and spray paint - only a temporary solution).
Solution: Replace drier, pull a vacuum charge of the system. If an R-22 system consider replacement.
Effect: This could cause or be the cause of other electrical failures. Electrical failures usually cause another failure that will be linked to the first. Loose connections cause heat, which causes over amperage, which causes melted wires, which causes burnt contactor points, which causes bad capacitors, which causes burnt fuses. Welded contactors will make the system run continuously, never turning off, resulting in frozen coils.
Solution: Replace the contactor when recommended or possibly every 5 years, for maintenance. Add a hard start kit to the system to reduce high amperage upon start up or when appropriate. Add a time delay to prevent short cycling. Have capacitor checked for proper microfarads and all wiring for being loose or overheated.
Replace contactor 30 - 40-amp
Effect: Burned wiring could cause fire, burnt or welded contactors, weak or bad capacitors, electrical shorts, blown fuses, failure of unit. Miss wired could cause failure of unit, blown fuses or inoperable system.
Solution: Repair or replace any burnt wires. Have all electrical checked for proper wire sizes and or fuse sizes.
Repair or replace wiring
Effect:Â Compressor will lock up, not start, draw high amps. Contactors will pit and the system will run hot.
Solution: Replace capacitor, add a hard start kit to system to lower amperage upon start up.
Replace weak or blown capacitor
Effect: Breakers will trip or fuses blow, unit will shut off, possible fire hazard, possible electrical hazard (electrical shock) Very dangerous, repair immediately.
Solution: Replace disconnect box with a new breaker panel with correctly sized breaker. Check breakers in the main panel as well for proper size. Purchase service contract!!!!
Replace disconnect box
Effect: Â Possible fire, if fuses are oversized for wire feeding fuse panel, the wire could burn before the fuse blows.
Solution: Make sure proper wire is run to disconnect and make sure fuses are not over rated for wire size. Technician will be able to determine proper fuse size, wire size and capacity of unit.
Replacement of fuse
Effect: Â Burned wiring could cause fire, burnt or welded contactors, weak or bad capacitors, electrical shorts, blown fuses, failure of unit. Inoperable system.
Solution: Repair or replace any burnt wires. Have all electrical checked for proper wire sizes and or fuse sizes. Replace fuses with new Breaker panel instead of fuses. Find out why the fuses are blown, burnt or discolored.
Effect: Possible electrical shock or hazard, could cause blown fuses or burnt wires.
Solution: Replace whip with correct size mount whip properly and secured to the wall with seal tight connectors properly installed. Purchase service contract!!!!
Replace electrical whip
Effect: Â Having no hard start kit, only effects the system when high amperage upon start up affects the system running. Having a hard start kit on the system allows for the compressor to start easily and proceed to the run mode. A blown hard start kit may be an indication of a bad compressor or faulty hard start kit.
Solution: Install a hard start kit when a compressor is drawing high amperage upon start up to enhance the performance of the system. Replace the hard start kit when it is blown for proper operation.
Hard start kit replacement
Effect: Sludge in the compressor. Loss of capacity, inefficient operation, increased wear and tear on compressor, muggy house, low humidity removal, loud compressor.
Solution: Properly check system verify super heat, sub cooling, delta tee, check for lack of air flow through system, dirty coil, dirty blower, ducts too small, restricted return, dirty filter.
There is a reason for a sweating compressor
Effect: Condensers that are in fair to poor condition will not remove the same heat load as a new one. Also, higher energy bills, more break downs and repairs will be inevitable.
 Solution: Consider replacement of system, when a system is in poor condition it would be beneficial to consider replacement, due to the amount money it cost for repairs and operation of existing systems.
Condenser in poor - fair condition
Effect: A shorted time delay will blow a low voltage fuse or burn a transformer. Also may not allow a system to come on. A system without a time delay is usually not protected from short cycling of system. A time delay will prevent a system from short cycling and protect against power surges.
Solution:Â Install a new time delay when there is none to prevent short cycling of the condenser or the one there is shorted or not working.
Replace or install time delay
Effect: During a power surge extreme high voltage will spike your electrical system therefore creating excessive voltage to the unit possibly shorting or grounding your compressor.
 Solution: Install a surge protector to protect from high voltage surges or power outages.
Effect: Possible kinking of the lines or restrictions occurring. Aesthetics are poor.
 Solution: secure lines possibly run new line set if needed.
Effect: The system will not cool properly or remove the heat from the house, the compressor may run hot and damage the compressor.
Solution: Run the correct copper lines for the system that is installed, also check ductwork and return for correct size.
 Solution: Repair or replace copper lines immediately.
Effect: The rubba tex helps keep the suction line cool which helps cool the compressor. This results in higher temperatures and efficiency loss.
Solution: Replace the rubba tex and check pressure and temperatures to make sure system is working to proper efficiency.
Rubba tex replacement
Effect:Â This could cause the system to get filthy dirty and cause low efficiency.
Solution:  Raise condenser and put on top of a slab. Install cinder blocks under slab to raise about 12’’ high.
Raise Slab
Effect: Higher energy bills, lack of capacity when needed.
Solution: Replace system with higher efficiency system to lower energy consumption.
Increase energy efficiency by considering a replacement system
Effect: Excessively expensive refrigerant, phasing out of production as of 2020, the cost of the refrigerant will be cost prohibitive to purchase.
Solution: Â There is only one solution and that is to replace the system with a 410-A unit. If your system needs refrigerant, we strongly consider replacement of the system.
R-22 systems will be cost prohibitive in near future
Effect: Â Dirty coils are one of the worst problems to have. This causes, low efficiency, low air flow, low cooling capacity, sweating vents, compressor sweating, damage to compressor, coil will freeze up, and water will leak from the coil once defrosted. This is the single worst problem for an a/c system. It must be cleaned or replaced.
Solution: A coil can be pulled and cleaned but this could be very expensive based on the installation of the coil. Also, keep in mind, there is no way of knowing if the compressor has been damaged due to the dirty coil. If the coil is dirty the blower will also need to be pulled and cleaned as well. Consider the cost of repairs to replacement.
Dirty evaporator coil, must be cleaned or replaced
Effect: low capacity, high humidity, high energy bills, overheated compressor, coil freezing up, excessive repair cost until leak is repaired or part is replaced. The costliest problem for a system.
Solution: Â A leak check can be performed several ways some more costly than others. Electronic leak check is the most cost effective. Isolate and pressure test system with dry nitrogen, proves it is leaking.
Leak check
Refrigerant leaks - R-22 systems (replace unit)
Effect: : if the drain pan clogs up the water will either 1. Go into an emergency pan 2. Push up a float switch to shut the unit off 3. Leak all over the floor or all over components of the heater, possibly shorting other components.
Solution: : Install a float switch on the main drain line to help prevent over flows, pull and clean coil and pan, install a U/v light in supply plenum to help kill mold and mildew. Purchase service contract!!!!
Unclog pan
Affect: Possible overflow of water onto the ceiling if the drain pan is not installed and secured properly.
Solution: Level and secure the pan, install a pan switch to prevent water from overflowing in the future.
Affect: Possible leaks on the ceiling.
Solution: Replace the pan, replace and repair drain lines, install float switches on the pan and on main drain line.
Effect: Â High energy bills, freezing coil, low capacity, not cooling, high humidity and uncomfortable house.
Solution: Replace the TXV
Replace the thermostatic expansion valve
Effect: High energy bills, freezing coil, low capacity, not cooling, high humidity and uncomfortable house.
Solution: Clear or replace piston is the only solution.
Change piston or clean
Effect: Restricted airflow, less capacity, hot spots or areas that don’t cool, loss of air in the attic causes high energy bills, negative pressure in the house, high humidity, poor Indoor air quality.
Solution: The plenum should be made to the size of the coil to fit properly, it should be secured with screws, tape and mastic, all leaks should be sealed. The design should be conducive to proper static pressure and CFM.
Leaky ducts could raise your energy bill as much as 30%
Poorly designed and leaking plenums need replacement or repair
Effect: Â Hot humid air being sucked into return, muggy air, unfiltered air, bad indoor air quality, high energy bills, dirty evaporator coils, high heat load, system will not cool properly, dirty blower wheel.
Solution: Seal all return plenum or rebuild restricted return plenum. Possibly enlarge the return or add additional return for proper airflow. Proper filter size H x W x 2 = CFM Example 24 x 24 x 2 = 1152 =3 tons .
Correctly size the return air and seal all leaks
Effect: High energy bills, excessive heat load, loss of air in the attic, sweating ducts, molded ducts, loss of heat and air conditioning.
Solution: Insulate existing hard pipe with new duct wrap R-8. Replace ductwork that is old and flexible with new R-8 flex duct. Possibly replace existing old hard pipe with new flexible duct for better efficiency.
Poor duct insulation means poor efficiency
Solution: Repair any ducts that are leaking, rewrap hard pipe, seal ducts, mastic tape and strap up ductwork to be secure. Leaky ducts could raise your energy bill as much as 30%
Repair all ductwork
Repair all ductwork & collars
Effect: Major air leaks cause major problems, high energy bills, high humidity, loss of capacity, negative pressure in the house, poor filtration, dust and indoor air quality issues. #1 problem in our industry
Solution: Seal all air leaks, replace or repair all minor and major leaks. Do all recommendations when it comes to air leaks because this is the #1 problem in our industry and will cost you the consumer the most money.
Repair all air leaks / job specific
Strongly consider all recommendations
Effect:  Leaking – high energy bills, high humidity, hot spots, continuous running of system, false readings from Thermostat. BROKEN STAIRS ARE – DANGEROUS - Broken legs, twisted ankles, cuts and scrapes from screws. Liability issues.
Solution: Have attic stairs replaced when broken, When there is none – To meet code and to allow proper access to the attic (have a new one installed) Leaking attic stairs – can be covered with an attic stair tent.
Repair, replace or cover stair cases for safety and energy consumption
Effect: Flooded floors, damaged ceilings, dripping over hangs. Water damage from clogged or leaking drain lines causes more damage than any other thing in the a/c business.
Solution: RUN NEW DRAIN LINE. You could have your drain line blown and un clogged and that may work for a while, but until its clean or replaced it will continue to give problems. Purchase service contract!!!!
Replace or repair drain lines
Effect: A peat trap is installed to prevent sewer gas from getting in home. Missing could cause drain problems. Clogged could cause water problems or open float switch.
Solution:Â Seal any drain lines, unclog or replace any drain pipe that may needs to be replaced. If no peat trap, have one properly installed.
Replace repair or unclog drain lines
Effect: No float switch puts your home at risk to flooding of water in the home or on the ceiling if emergency pans are not properly installed. If drain lines clog the water has to go somewhere.
Solution: Recommendation install a float switch on the main drain line and on an emergency pan to help protect floors and ceilings from overflow of water.
Effect: Broken float switch is usually found when there is water on the floor or ceiling.
Solution: Broken float switch needs to be replaced or have a new switch installed.
Replace or repair float switch when damaged or missing
Effect: Either the condenser will not come on or the entire system will not come on because the switch opens a circuit to break contact in the unit.
Solution: Clear the drain line, install a blow out valve for clearing the lines, REPLACE all the drain lines and start over with new lines make sure they're all clean.
Effect: No float switch or broken switch is usually found when there is water on the floor or ceiling. An open float switch means it worked and stopped your system from running this protected your home from damage.
Solution: Open switch -Clear the drain lines or consider replacing the drain lines since they are as old as the house and normally are not maintained. Broken or no switch – replace or install a new one.
Effect: Return air leaks, cause high energy bills. Unlevel platforms cause water issues the drain is on the higher side of the unit or the unit is leaning and the water overflows he pan.
Solution: Build a new platform, which may require removing the heater and completely rebuilding and supporting system properly.
Rebuild damaged platform
Effect: VERY DANGEROUS, no catwalk or unsecured catwalks could cause falls from the attic through the ceiling on to the floor possibly severely hurting someone.
Solution: The system is not up to code, secure and install a safe catwalk with lighting for everybody’s benefit.
For safety reasons alone install a secured catwalk!
Effect: Water damage on the heater when dripping water from above the unit. Constant drips in the emergency pan could cause a rusted pan.
Effect: Â High energy bills, a/c runs all the time, oversized a/c system for house, high humidity.
Solution: Insulate the attic with cellulose, bring to an R-30 10’’ of insulation.
We can insulate your attic for you.
Effect: a/c system not working or temperatures are off from set point.
Solution: Â Replace with digital thermostat, programmable or even a WiFi thermostat.
Repair or replace defective thermostats.
Effect: No U/v light – mold growth, mildew, bacteria, viruses grow. With a u/v light it will Kill Mold, Mildew, air born contaminants, viruses bacteria, helps keep a healthy home.
Solution: Â Ask about our filtration systems with u/v lights, or individual light to be installed in the supply or return plenum.
Please ask about having a healthier home
$600.00Â - $1,200.00
Effect: Noisy when running or blower does not work – unit freezes up, no air flow out of vents, house gets hot.
Solution:Â Replace the blower motor, clean the motor and wheel make sure it is balanced. Possibly replace furnace.
Repair or replacement of blower motor
Effect: Poor air quality, high humidity, muggy home, hot spots, breezy home, high energy bills, uncomfortable home.
Solution: Consider replacement system, variable speed or two stage systems, whole home dehumidifiers, filtration systems, sealing ductwork, replacing ducts, clean and maintain system annually, install U/V lights or filtration systems. We can do all the work that it takes to make you home a healthier place to live.
Consider all solutions and make proper decisions for your home
Effect: Improper air flow, Noisy blower, high energy cost, sweating grills, loss of capacity, compressor failure, sweating ducts, shorter life on unit.
Solution: Replace or clean blower wheel and compartment, possibly need to clean evaporator as well. Replace unbalanced wheels.
Repair, replace or clean blower wheel.
 Effect: Dirty blower, coils, cabinets, loss of airflow, BTU capacity, sweating ducts and grills, system doesn’t cool, unit may freeze up. Could cause major damage to system.
Solution: Most people don’t know about what is out there for better filtration and indoor air quality. Ask the technician about a P.C.O. kit, or Media filters.
Fair or poor filtration can be upgraded.
Media filters and P.C.O. kits.
Effect: Indoor air quality, issues.
Solution: Clean the cabinet and filter the system better, install a good filtration system  .
Clean the blower cabinet and filter system properly
Effect: Dirty blower, coils, cabinets, loss of airflow, BTU capacity, sweating ducts and grills, system doesn’t cool, unit may freeze up. Could cause major damage to system.
Solution: Change filters regularly, install good pleated filters, Install media filters or P.C.O filtration systems.
Lack of filtration will cause major problems
Media or P.C.O Filtration
LIMITED WARRANTY: all materials, parts and equipment are warranted by the manufacturers’ or suppliers’ written warranty only. All labor performed by the above named company is warranted for (30) days or as otherwise indicated in writing. The above named company makes no other warranties, express or implied, and its agents or technicians are not authorized to make any such warranties on behalf of above named company. In the case of refrigerant (freon) leak repairs, our parts and labor warranty is as stated above with the following clarifications: a. You are strongly urged to let the technician show you the location of the leak prior to and after the repair. If this is not possible due to attic or other inconvenient location, be sure the technician accurately describes the leak location on his service ticket. Our warranty is for the specific leak repaired. b. Unfortunately, many times there can be more than one leak in a system. We may only locate one and complete an effective repair only to be called out again later to find another one. Our warranty on the previous leak repair would not cover the new one. However, if within (30) days of the first leak location, there will be no service charge to return to the house. You will then only pay for the repair of the leak, just as you would have done if we had located it on the first trip. FORM 200A SERVICE INVOICE (A/C)